Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Brasília; CONITEC; mar. 2022.
Non-conventional in Portuguese | LILACS, ColecionaSUS | ID: biblio-1378099

ABSTRACT

CONTEXTO: Os PCDT são documentos que visam garantir o melhor cuidado de saúde diante do contexto brasileiro e dos recursos disponíveis no SUS. Podem ser utilizados como materiais educativos aos profissionais de saúde, auxílio administrativo aos gestores, regulamentação da conduta assistencial perante o Poder Judiciário e explicitação de direitos aos usuários do SUS. Os PCDT são os documentos oficiais do SUS que estabelecem critérios para o diagnóstico de uma doença ou agravo à saúde; tratamento preconizado, com os medicamentos e demais produtos apropriados, quando couber; posologias recomendadas; mecanismos de controle clínico; e acompanhamento e verificação dos resultados terapêuticos a serem seguidos pelos gestores do SUS. Os PCDT devem incluir recomendações de condutas, medicamentos ou produtos para as diferentes fases evolutivas da doença ou do agravo à saúde de que se tratam, bem como aqueles indicados em casos de perda de eficácia e de surgimento de intolerância ou reação adversa relevante,


Subject(s)
Clinical Protocols , Macular Degeneration/diagnosis , Macular Degeneration/drug therapy , Macular Degeneration/therapy , Photochemotherapy/instrumentation , Unified Health System , Brazil , Fluorescein Angiography/instrumentation , Laser Coagulation/instrumentation , Vascular Endothelial Growth Factor A/therapeutic use , Bevacizumab/therapeutic use , Ranibizumab/therapeutic use , Slit Lamp Microscopy/instrumentation
2.
Arq. bras. oftalmol ; 82(5): 381-388, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019440

ABSTRACT

ABSTRACT Purpose: To evaluate the effectiveness in in­traocular pressure reduction and safety of micropulse trans­scleral diode cyclophotocoagulation in refractory glaucoma. Methods: We prospectively evaluated a case series of 21 eyes of 21 consecutive patients with refractory glaucoma treated with micropulse transscleral diode cyclophotocoagulation at 12-month follow-up. The total treatment time was at the discretion of the surgeon, considering baseline and target intraocular pressure and glaucoma diagnosis. Intraocular pressure, inflammation, visual acuity, and number of medications were monitored. Success was defined as intraocular pressure between 6 and 21 mmHg and/or 30% reduction from baseline intraocular pressure with or without the use of antiglaucoma medications. Visual acuity loss was defined as a loss of ≥2 lines of vision on the Snellen chart or a ≥2-level decrease in visual function in patients with nonmeasurable chart acuity. Results: The mean age was 61.04 ± 12.99 years, and 11 (52.4%) patients were male, with most (95%) patients showing low visual acuity at baseline (count fingers or worse). The mean intraocular pressure was 33.38 ± 15.95 mmHg, and the mean number of medications was 3.5 ± 1.1 at baseline. After 1, 3, 6, and 12 months, 76.19%, 57.14%, 55.56%, and 66.67%, respectively, of the patients were classified as treatment successes. Seven (33.3%) patients required new laser treatment and were considered treatment failures. The mean intraocular pressure reduction was 44.72% ± 29.72% in the first week and 41.59% ± 18.93% at the end of follow-up (p=0.006). The mean number of medications significantly dropped to 2.00 ± 1.7 at the 12-month visit (p=0.044). Complications included hypotony (4.8%), intraocular inflammation after 1 month (19%), and visual acuity loss (4.8%). Conclusions: Micropulse transscleral diode cyclophotocoagulation was safe and effective for reducing intraocular pressure in eyes with refractory and advanced glaucoma, with reduced need for ocular antihypertensive medication.


RESUMO Objetivo: Avaliar a eficácia na redução da pressão intraocular e na segurança da ciclofotocoagulação com laser de diodo transescleral em glaucoma refratário. Métodos: Avaliamos prospectivamente uma série de casos de 21 olhos de 21 pacientes com glaucoma refratário tratados com ciclofotocoagulação com laser de diodo transescleral com acompanhamento por 12 meses. O tempo total de tratamento ficou a critério do cirurgião, considerando a pressão intraocular inicial e alvo e o tipo de glaucoma. Pressão intraocular, inflamação, acuidade visual e número de medicamentos foram monitorados. O sucesso foi definido como pressão intraocular entre 6 e 21 mmHg e/ou redução de 30% da pressão intraocular basal com ou sem o uso de medicamentos glaucomatosos. Perda da acuidade visual foi definida como perda de ≥2 linhas de visão na tabela de Snellen ou uma diminuição de ≥ 2 níveis na função visual em pacientes com acuidade do gráfico não mensurável. Resultados: A idade média foi de 61,04 ± 12,99 anos e 11 (52,4%) pacientes eram do sexo masculino, com a maioria (95%) dos pacientes apresentando baixa acuidade visual inicialmente (conta dedos ou pior). A pressão intraocular média foi de 33,38 ± 15,95 mmHg, e o número médio de medicamentos foi de 3,5 ± 1,1, no início do estudo. Após 1, 3, 6 e 12 meses, 76,19%, 57,14%, 55,56% e 66,67%, respectivamente, dos pacientes foram classificados como sucesso do tratamento. Sete (33,3%) pacientes necessitaram de novo tratamento com laser e foram considerados falhas no tratamento. A redução média da pressão intraocular foi de 44,72% ± 29,72% na primeira semana e 41,59% ± 18,93% no final do seguimento (p=0,006). O número médio de medicamentos diminuiu significativamente para 2,00 ± 1,7 na visita de 12 meses (p=0,044). As complicações incluíram hipotonia (4,8%), inflamação intraocular após 1 mês (19%) e perda de acuidade visual (4,8%). Conclusões: A ciclofotocoagulação com laser de diodo transescleral foi segura e eficaz para reduzir a pressão intraocular em olhos com glaucoma refratário e avançado, com necessidade reduzida de hipotensores oculares.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma/surgery , Laser Coagulation/methods , Visual Acuity , Glaucoma/physiopathology , Glaucoma, Neovascular/surgery , Ciliary Body/surgery , Ciliary Body/physiopathology , Prospective Studies , Laser Coagulation/instrumentation , Intraocular Pressure
3.
Arq. bras. oftalmol ; 79(1): 15-18, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-771899

ABSTRACT

ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS) and visual analog scale (VAS) by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males) diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57). The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042) and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034) scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.


RESUMO Objetivo: Comparar as respostas de dor de pacientes com retinopatia diabética proliferativa (PDR) submetidos à panfotocoagulação retiniana (PRP) usando laser de padrão de varredura (PASCAL) ou fotocoagulação navegada a laser (NAVILAS). Métodos: Pacientes com diagnóstico de PDR foram aleatoriamente designados para submeter-se ao tratamento de fotocoagulação com PASCAL ou NAVILAS. A PRP foi realizada no modo "multi-shot" com diâmetro do laser de 200-400 µm e duração do pulso de 30 ms, utilizados para se obter uma mancha branca-acinzentada na retina. Os parâmetros foram idênticos em ambos os procedimentos. Após 30 minutos da PRP, os pacientes foram solicitados a descrever verbalmente a sua percepção da dor como quer "nenhuma," "leve," "moderada," "intensa" ou "dor muito intensa" por meio de uma escala de avaliação verbal (VRS) e também por meio de uma escala visual analógica (VAS), indicando uma pontuação de "0" a "10" representando a intensidade da dor de "nenhuma dor" a "dor intensa." Resultados: Um total de 60 olhos de 60 pacientes (20 mulheres e 40 homens) com diagnóstico de PDR foram tratados. A média de idade dos pacientes foi de 62,22 ± 9,19 anos e a média de duração da diabete foi 195.47 ± 94,54 meses. O número médio de pulsos de laser emitidos durante a PRP foi 389,47 ± 71,52 no grupo NAVILAS e 392,70 ± 54,33 no grupo PASCAL (p=0,57). A diferença nas respostas de dor entre os pacientes nos grupos NAVILAS e PASCAL foi significativa em relação às médias de VRS (1,10 ± 0,67 e 1,47 ± 0,69; p=0,042) e VAS (2,13 ± 1,17 e 2,97 ± 1,35; p=0,034). Conclusões: As respostas de dor em pacientes submetidos à PRP com pulsos de 30 ms de duração foram significativamente menores nos pacientes do grupo NAVILAS em relação ao grupo PASCAL.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Diabetic Retinopathy/surgery , Eye Pain/prevention & control , Laser Coagulation/methods , Pain Measurement , Laser Coagulation/instrumentation , Random Allocation , Reproducibility of Results , Severity of Illness Index , Statistics, Nonparametric , Time Factors , Treatment Outcome , Visual Analog Scale
4.
Indian J Ophthalmol ; 2011 Mar; 59(2): 87-91
Article in English | IMSEAR | ID: sea-136148

ABSTRACT

Aim: To systematically refine and recommend parameter settings of spot size, power, and treatment duration using the Pascal® photocoagulator, a multi-spot, semi-automated, short-duration laser system. Materials and Methods: A retrospective consecutive series with 752 Caucasian eyes and 1242 laser procedures over two years were grouped into, (1) 374 macular focal / grid photocoagulation (FP), (2), 666 panretinal photocoagulation (PRP), and (3) 202 barrage photocoagulation (BP). Parameters for power, duration, spot number, and spot size were recorded for every group. Results: Power parameters for all groups showed a non-gaussian distribution; FP group, median 190 mW, range 100 – 950 mW, and PRP group, median 800 mW, range 100 – 2000 mW. On subgroup comparison, for similar spot size, as treatment duration decreased, the power required increased, albeit in a much lesser proportion than that given by energy = power × time. Most frequently used patterns were single spot (89% of cases) in FP, 5 × 5 box (72%) in PRP, and 2 × 2 box (78%) in BP. Spot diameters as high as ≈ 700 μm on retina were given in the PRP group. Single session PRP was attempted in six eyes with a median spot count of 3500. Conclusion: Overall, due to the small duration of its pulse, the Pascal® photocoagulator tends to use higher powers, although much lower cumulative energies, than those used in a conventional laser. The consequent lesser heat dissipation, especially lateral, can allow one to use relatively larger spot sizes and give more closely spaced burns, without incurring significant side effects.


Subject(s)
Automation , Diabetes Complications/surgery , Diabetic Retinopathy/surgery , White People , Humans , Laser Coagulation/instrumentation , Laser Coagulation/standards , Laser Coagulation/statistics & numerical data , Macular Edema/surgery , Normal Distribution , Retinal Perforations/surgery , Retrospective Studies , Time Factors
5.
Rev. chil. cir ; 50(6): 655-8, dic. 1998.
Article in Spanish | LILACS | ID: lil-243820

ABSTRACT

Se presenta un estudio prospectivo randomizado de 40 pacientes, divididos en dos grupos semejantes, a los que se realizó una hemorroidectomía abierta con electrobisturí y con láser de CO2: Los resultados de ambos grupos con respecto a la morbilidad y mortalidad postoperatoria inmediata y tardía fueron similares. Sólo 2 pacientes del grupo control (10 por ciento) presentaron sangrado postoperatorio, y en un paciente de cada grupo (5 por ciento) se observó retardo de cicatrización. No hubo infecciones ni estenosis anal. Se evaluó el dolor postoperatorio utilizando la escala visual análoga del dolor. Los controles se realizaron a las 2, 4, 8 y 24 horas. El grupo láser presentó menos dolor en las primeras 8 horas de la cirugía, pero no hubo diferencias luego de las 24 horas de operados. No hubo diferencias en la necesidad de analgesia extra. La hemorroidectomía láser no presenta ventajas claras en cuanto a morbimortalidad, dolor y evolución con respecto a la cirugía tradicional de las hemorroides


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Hemorrhoids/surgery , Laser Coagulation/instrumentation , Laser Coagulation/methods , Electrocoagulation/instrumentation , Electrocoagulation/methods , Prospective Studies , Wound Healing
6.
Indian J Ophthalmol ; 1991 Jul-Sep; 39(3): 115-7
Article in English | IMSEAR | ID: sea-70622

ABSTRACT

Knowledge of optics, comparative magnification and working field of view is essential for rational use of ophthalmoscopic contact lenses for retinal photocoagulation. The three commonly used contact lenses are described and compared.


Subject(s)
Contact Lenses , Humans , Laser Coagulation/instrumentation , Optics and Photonics , Retinal Diseases/surgery
SELECTION OF CITATIONS